Drolet Rocket E.P.A Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Herde Drolet Rocket E.P.A herunter. Drolet Rocket E.P.A Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
45521A
Printed in Canada
27-03-2012
ROCKET E.P.A. WOOD STOVE
OWNER’S MANUAL
US ENVIRONMENTAL
PROTECTION AGENCY PHASE
II CERTIFIED WOOD STOVE
Safety tested according to ULC
S627 and UL 1482 Standards
by:
READ AND KEEP THIS MANUAL FOR REFERENCE
STOVE BUILDER INTERNATIONAL INC.
250, de Copenhague, Saint-Augustin-de-Desmaures (Quebec), Canada G3A 2H3
Tel: (418) 878-3040
Fax: (418) 878-3001
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use
of information contained in any manual obtained from unauthorized sources.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - OWNER’S MANUAL

45521A Printed in Canada 27-03-2012 ROCKET E.P.A. WOOD STOVE OWNER’S MANUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STO

Seite 2

10 Graphic 2 A- 1 in.(25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- 0.024’’ (0.61mm) sheet metal. Graphic 3 A- 1 in. (25 m

Seite 3 - TABLE OF CONTENTS

11 Graphic 5 A- 1 in. (25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- Brick. Graphique 6 A- 1 in. (25 mm) minimum; 1- Comb

Seite 4 - SECTION 1.0 - INSTALLATION

12 SECTION 2.0 CHIMNEY (FLUE SYSTEM) 2.1 DEFINITIONS For clarity, the following definitions should be used with respect to these instructions:  A c

Seite 5 - PROTECTOR

13 If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the Building Code. It must be lined

Seite 6

14 FIGURE 2.2 Minimum Height of the Chimney 2.2.1 Step by step installation of your factory-built chimney The way to install your chimney may vary

Seite 7

15 Stove pipe  An adequate number of stove pipe sections.  A 90o elbow Typical installation through the wall FIGURE 2.2.1 (A) Typical installat

Seite 8 - With Shielding

16 2- Once the opening completed, you need to frame in the area to allow for the installation of a wall thimble. A wall thimble is not required for

Seite 9

17 5- You can now install the wall support. Simply slide the wall support up to the tee, ensuring that the adapter on the support engages with the f

Seite 10

18 8- Finally, twist on your rain cap and you can head back inside. 9- You are now ready to connect your chimney to your stove. Simply install

Seite 11

19 Typical installation through the ceiling FIGURE 2.2.1 (B) Typical Installation Through the Ceiling 1. Place your stove where you would like i

Seite 12 - 2.2 CHIMNEY

2 INTRODUCTION Stove Builder International, one of the most important wood stove and fireplace manufacturers in North America, congratulates you on y

Seite 13

20 2. Before you install the ceiling support, you need to frame the area. 3. To install the ceiling support, just slide the assembly into the f

Seite 14 - Wallsupportsystem

21 6. Now, you can add additional chimney sections. Continue adding chimney lengths until a height of about 2 feet below the next ceiling level. An a

Seite 15 - Stove pipe

22 8. Next, slide the storm collar down the chimney until it contacts the flashing. Tighten the nut and bolt and seal the collar to the chimney with

Seite 16

23 2.2.2 Typical installation through an existing masonry chimney You can also install your stove using your existing masonry chimney. To do so, fol

Seite 17

24 FIGURE 2.2.2 (B) Factory Built Thimble

Seite 18 - Ceilingsupportsystem

25 FIGURE 2.2.2 (C) Brick Thimble

Seite 19

26 2.3 CHIMNEY CONNECTOR Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the stove’s exhaust outlet. T

Seite 20

27 FIGURE 2.3 (B) Minimum Slope  The assembly should be as short and direct as possible between the stove and chimney (See figure 2.4 (A)). The u

Seite 21

28 2.4 DRAFT Your E.P.A Drolet stove’s performance will be optimised if it is installed with a chimney (flue) system that provides an adequate draft

Seite 22

29 2.6 THE ADVANTAGE OF INSTALLING A BLOWER (FAN) A blower can be installed at the back of your DROLET stove. This option is necessary if you wish to

Seite 23 - Masonry Chimney

3 TABLE OF CONTENTS SECTION 1.0 - INSTALLATION ... 41.1 GENERAL INSTALLATION ...

Seite 24

30 SECTION 3.0 OPERATION Keep these instructions for future reference. WARNINGS:  ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED I

Seite 25

31  Even though your E.P.A Drolet has been specifically designed and tested to prevent smoke spillage, always open the door slowly as this will mini

Seite 26 - 2.3 CHIMNEY CONNECTOR

32 3.2 FUEL Fuel for the stove must not be stored closer than the required clearances to combustibles (heat sensitive materials). NEVER STORE WOOD IN

Seite 27 - FIGURE 2.4 The use of elbows

33 3.2.1 The use of manufactured logs There are numerous types of manufactured logs sold on the market. You must be very careful with this type of

Seite 28 - 2.5 OUTSIDE COMBUSTION AIR

34 3.4 LIGHTING A FIRE  Place enough crumpled balls of newspaper or other paper into the stove to cover the bottom of the firebox.  Place small

Seite 29

35 3.5 MAINTAINING THE FIRE Once the wood has been consumed (or partially consumed) and you have obtained a good bed of embers, you should reload the

Seite 30 - SECTION 3.0 OPERATION

36 SECTION 4.0 MAINTENANCE 4.1 CLEANING AND PAINTING YOUR STOVE Clean the stove frequently so that soot, ash, and creosote do not accumulate. Speci

Seite 31

37 4.4 CHIMNEY (FLUE) CLEANING Regular chimney (flue) maintenance, as well as good burning practices, is required to prevent chimney fires. When wood

Seite 32 - 3.2 FUEL

38 SECTION 5.0 FEATURES 5.1 ROCKET STOVE Type of fuel : Wood Test standard : ULC S627 and UL 1482 Recommended surface : 250 to 1000 sq. ft. H

Seite 33 - 3.3 NOTES ABOUT FIRST FIRING

39 BRICK LAYOUT ITEM PART # DESCRIPTION QTY 1 29010 4 ½” X 9” BRICK 12 2 29010-CUT 4 1/2'” X 9” BRICK (CUT) 2 3 29015 4” X 9” BRICK

Seite 34 - FIGURE 3.1 Air control

4 SECTION 1.0 - INSTALLATION When installed and operated as described in these instructions, the E.P.A Rocket wood stove is suitable for use as a fre

Seite 35 - 3.6 FAN (BLOWER) OPERATION

40 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This war

Seite 36 - SECTION 4.0 MAINTENANCE

5 1.2 POSITIONING THE STOVE It is very important to position the wood stove in an area that will favour the most efficient heat distribution througho

Seite 37 - 4.4 CHIMNEY (FLUE) CLEANING

6 FIGURE 1.3 Clearances to combustible materials and floor protection

Seite 38 - SECTION 5.0 FEATURES

7 Floor protector If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible material as shown on figure

Seite 39

8 TYPE OF PROTECTION Reducing Clearances With Shielding Sides and Rear/Back Top Sheet metal, a minimum of 0,024" (0,61mm) spaced out at least 1&

Seite 40

9 Graphic 1 A- Minimum clearance required between the appliance and an unshielded combustible ceiling. B- 20 in. (500 mm) minimum; C- 1 in. (25 mm) m

Kommentare zu diesen Handbüchern

Keine Kommentare