READ AND KEEP THIS MANUAL FOR REFERENCE
OWNER’S MANUAL
ESCAPE 1800 EPA WOOD STOVE
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
STOVE
Verified and tested following
ULC S627 and UL 1482 Standards
by:
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : (418 ) 527-3060
Fax : (418 ) 527-4311
www.drolet.ca
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - ESCAPE 1800 EPA WOOD STOVE

READ AND KEEP THIS MANUAL FOR REFERENCE OWNER’S MANUAL ESCAPE 1800 EPA WOOD STOVE US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD S

Seite 2

9If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the Building Code. It must be lined w

Seite 3 - TABLE OF CONTENTS

10 FIGURE 2.2 Minimum Height of the Chimney 2.2.1 Step by step installation of your factory-built chimney The way to install your chimney may var

Seite 4 - SECTION 1.0 - INSTALLATION

11Typical installation through the wall FIGURE 2.2.1 (A) Typical installation through the wall 1- Start by positioning your stove where you woul

Seite 5 - 1.3 CLEARANCES

122- Once the opening completed, you need to frame in the area to allow for the installation of a wall thimble. A wall thimble is not required for

Seite 6

13 6- You can start to add chimney sections. We recommend that you also use locking bands to secure all connections.

Seite 7

148- Finally, twist on your rain cap and you can head back inside. 9- You are now ready to connect your chimney to your stove. Simply install

Seite 8 - FIGURE 1.4 Floor protector

15 Typical installation through the ceiling FIGURE 2.2.1 (B) Typical Installation Through the Ceiling 1. Place your stove where you would lik

Seite 9 - 2.2 CHIMNEY

16 2. Before you install the ceiling support, you need to frame the area. 3. To install the ceiling support, just slide the assembly into the

Seite 10

17 6. Now, you can add additional chimney sections. Continue adding chimney lengths until a height of about 2 feet below the next ceiling level. A

Seite 11

18 9. You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe

Seite 12

1INTRODUCTION Stove Builder International, one of the most important wood stove and fireplace manufacturers in North America, congratulates you on y

Seite 13

19 FIGURE 2.2.2 (A) Typical Installation Through an Existing Masonry Chimney

Seite 14

20FIGURE 2.2.2 (B) Factory Built Thimble

Seite 15

21 FIGURE 2.2.2 (C) Brick Thimble 2.3 CHIMNEY CONNECTOR Your chimney connector (commonly called stove pipe) and chimney must have the same diamet

Seite 16

22 FIGURE 2.3 (A) Connecting Sections 1/4" RISE PER FOOT FIGURE 2.3 (B) Minimum Slope

Seite 17

232.4 DRAFT Your E.P.A Drolet stove’s performance will be optimised if it is installed with a chimney (flue) system that provides an adequate draft

Seite 18

242.6 THE ADVANTAGE OF INSTALLING A BLOWER (FAN) A blower can be installed at the back of your E.P.A Drolet stove. This option is necessary if you

Seite 19

25SECTION 3.0 OPERATION Keep these instructions for future reference. WARNING: • ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED

Seite 20

263.1 SAFETY INFORMATION • These stoves are designed for safe operation WHEN BURNING WOOD ONLY. Altering or modifying the unit or installation wi

Seite 21

27• Although the ceramic glass is extremely durable under any normal use, a few precautions are required. Do not attempt to push logs further into t

Seite 22 - 2.3 CHIMNEY CONNECTOR

28 Wood species Energy yield (millions of BTU/cord) Oak 29 Sugar Maple 28 Beech 26 Yellow birch 25 Ash 24 High energy yield Elm 23 Larch (Tamarack

Seite 23 - 1/4" RISE PER FOOT

2TABLE OF CONTENTS 1.1 GENERAL INSTALLATION...

Seite 24 - 2.5 OUTSIDE COMBUSTION AIR

293.2.2 Simple wood moisture test Add one large piece of wood to the top of an established fire. If it starts to burn on three sides within one mi

Seite 25

30Intensity Draft Setting Low Push Control to end of travel. Medium Low Pull Control by 3/8” from closed position. Medium High Pull Control by 3/4

Seite 26 - SECTION 3.0 OPERATION

313.5 MAINTAINING THE FIRE Once the wood has been consumed (or partially consumed) and you have obtained a good bed of embers, you should reload th

Seite 27 - 3.1 SAFETY INFORMATION

32SECTION 4.0 MAINTENANCE 4.1 CLEANING AND PAINTING YOUR STOVE Clean the stove frequently so that soot, ash, and creosote do not accumulate. Do

Seite 28 - 3.2 FUEL

334.3 GASKETING It is recommended that you change the door gasket (which makes your stove door air tight) once a year, in order to insure good contr

Seite 29

344.5 CHIMNEY (FLUE) CLEANING Regular chimney (flue) maintenance, as well as good burning practices, are required to prevent chimney fires. When wo

Seite 30 - 3.4 LIGHTING A FIRE

354.6 BAFFLE INSTALLATION FOR ESCAPE 1800 MODEL All firebrick and ceramic wool baffles must be properly in place for correct burning operation. Ha

Seite 31 - Figure 3.4

36 Figure 4.6.1 (B) - Firebrick layout for Escape 1800 model

Seite 32 - 3.6 FAN (BLOWER) OPERATION

374.5 SECONDARY AIR TUBE REPLACEMENT (see Figure 4.11) 1. Remove cotter pin at RH end of tube. 2. Slide tube to left and lower tube end below RH

Seite 33 - SECTION 4.0 MAINTENANCE

38SECTION 5.0 SPECIFICATIONS Fuel Type Cordwood Test Standards ULC S627 (CSA B366.2) & UL 1482 residential. Heat Output

Seite 34 - IN A COMBUSTIBLE CONTAINER

3SECTION 1.0 - INSTALLATION When installed and operated as described in these instructions, the Escape 1800 EPA wood stove is suitable for use as a

Seite 35 - 4.5 CHIMNEY (FLUE) CLEANING

39 1700, Léon-Harmel street, Quebec (Quebec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : ht

Seite 36

41.2 POSITIONING THE STOVE It is very important to position the wood stove in an area that will favour the most efficient heat distribution throug

Seite 37

5 Figure 1.3 Clearances to combustible materials

Seite 38 - Model Type of tube

61.3.1 Reduced clearances using shielding You may decrease the minimum clearances to combustible materials by installing heat radiation shields bet

Seite 39 - SECTION 5.0 SPECIFICATIONS

71.4 FLOOR PROTECTOR If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible material extending at le

Seite 40

8SECTION 2.0 CHIMNEY (FLUE SYSTEM) 2.1 DEFINITIONS For clarity, the following definitions should be used with respect to these instructions: • A

Kommentare zu diesen Handbüchern