OWNER`S MANUAL
DROLET EPA WOODSTOVES
HT-1200 HT-1600 HT-2000
990810/45060A_Feb 03
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOODSTOVES
Vérified and tested following
ULC S627 et UL 1482 Standards by:
Intertek Testing Services
READ AND KEEP THIS MANUAL FOR REFERENCE
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
1700, Léon-Harmel, Québec (Québec) G1N 4R9
Tel : ( 418 ) 527-3060
Fax : ( 418 ) 527-4311
www.drolet.ca
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - HT-1200 HT-1600 HT-2000

OWNER`S MANUAL DROLET EPA WOODSTOVES HT-1200 HT-1600 HT-2000 990810/45060A_Feb 03 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED

Seite 2 - TABLE OF CONTENTS

DOOR ADJUSTMENT In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust: • Rem

Seite 3 - INTRODUCTION

THE BENEFITS OF INSTALLING A BLOWER A blower can be installed at the back of your DROLET stove. This option is necessary if you wish to redistribute

Seite 4 - TECHNICAL SPECIFICATIONS

11INSTALLATION SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATI

Seite 5 - ASSEMBLY

FLOOR PROTECTOR Your wood stove should be placed on a non-combustible surface. The floor protector should be under the stove, eighteen inches beyond t

Seite 6

CLEARANCES It is of utmost importance that the clearances to combustible material be scrupulously respected upon installation of the stove you have s

Seite 7

14REDUCED CLEARANCES You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat

Seite 8

15CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL

Seite 9

CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recomm

Seite 10 - DOOR ADJUSTMENT

TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING18" CLEARANCEWALL SUPPORTWALL RADIATION SHIELDRAIN CAP Wall installation CEILING

Seite 11

MASONRY CHIMNEY: Clay liner Thimble Clean out door 18

Seite 12 - INSTALLATION

1 TABLE OF CONTENTS INTRODUCTION...2

Seite 13

FACTORY BUILT THIMBLE: 19

Seite 14 - CLEARANCES

BRICK THIMBLE: 20

Seite 15 - Shielding

21WOODSTOVE UTILIZATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials s

Seite 16 - CHIMNEY

22Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the gro

Seite 17

HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for ea

Seite 18 - TYPICAL INSTALLATIONS

24RELOADINGOnce you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to maximum a few second

Seite 19 - Clean out

25ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold

Seite 20

26MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require little maintenance. It is important to perform a visual inspection o

Seite 21

1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : [email protected] web site : www.drolet.ca LIMI

Seite 22 - WOODSTOVE UTILIZATION

2INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to

Seite 23 - IGNITION

3TECHNICAL SPECIFICATIONS HT-1200 HT-1600 HT-2000 Combustion Type: Wood Wood Wood Recommended Surface 600 à 1 200 ft2900 à 1 600 ft21 000 à 2 00

Seite 24 - HEATING

ASSEMBLY PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION Figure 1: HT-1200 Deluxe Pedestal Installation : 1. Remove all bricks and insulations in th

Seite 25 - RELOADING

BRICKS INSTALLATION (HT-1200) Figure 3: HT-1200 & HT-1200 DELUXE Bricks • Refractory bricks are to be installed according to figure 4.

Seite 26 - ASH DISPOSAL

BRICKS AND INSULATION INSTALLATION (HT-1600) 1. Remove from the stove all bricks and insulation. 2. Install all side bricks (12 x 4 1/2" x 9&q

Seite 27 - MAINTENANCE

BRICK AND INSULATION INSTALLATION (HT-2000) The stove is normally supplied with secondary air tubes in position. To install the baffle bricks and wh

Seite 28 - LIMITED LIFETIME WARRANTY

AIR TUBES INSTALLATION (HT-2000): The secondary air tubes are painted different colours . The back tube is yellow, the middle on is red and the front