READ AND KEEP THIS MANUAL FOR REFERENCE
45554A
Printed in Canada 11-09-2014
Installation and Operation Manual
Escape 1800 Insert
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD INSERT
Safety tested according to ULC S628,
UL 737 and UL 1482 Standards
by Intertek Testing Services
www.drolet.ca
Stove Builder International Inc.
250, rue de Copenhague, St-Augustin-de-Desmaures
(Quebec) Canada G3A 2H3
Tel: (418) 878-3040 Fax: (418) 878-3001
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Seitenansicht 0
1 2 3 4 5 6 ... 62 63

Inhaltsverzeichnis

Seite 1 - Escape 1800 Insert

READ AND KEEP THIS MANUAL FOR REFERENCE 45554A Printed in Canada 11-09-2014 Installation and Operation Manual Escape 1800 Insert US ENVIRONMENT

Seite 2

Escape 1800 Insert Installation and Operation Manual 10 2.2 Zone Heating and How to Make it Work for You Your new Escape 1800 wood insert is a sp

Seite 3

Escape 1800 Insert Installation and Operation Manual 11 your time will be warmest, while bedrooms and basement (if there is one) will stay cooler. I

Seite 4

Escape 1800 Insert Installation and Operation Manual 12 Vermiculite is used for the baffle. Vermiculite is a mineral. Large commercial mines exist i

Seite 5

Escape 1800 Insert Installation and Operation Manual 13 3 Fuel 3.1 Materials That Should Not be Burned • GARBAGE OF ANY KIND, • COAL OR CHARCOAL,

Seite 6 - 1 Safety Information

Escape 1800 Insert Installation and Operation Manual 14 3.2.3 Log Length Logs should be cut at least 1” (25 mm) shorter than the firebox so they fi

Seite 7

Escape 1800 Insert Installation and Operation Manual 15 3.2.5 How to Dry Firewood Firewood that is not dry enough to burn is the cause of

Seite 8 - 2 General Information

Escape 1800 Insert Installation and Operation Manual 16 3.2.6 Judging Firewood Moisture Content You can find out if some firewood is dry enough to

Seite 9

Escape 1800 Insert Installation and Operation Manual 17 4 Operating Your Insert 4.1 The use of a fire screen. This insert has been tested for use

Seite 10

Escape 1800 Insert Installation and Operation Manual 18 4.3.1 Conventional Fire Starting The conventional way to build a wood fire is to bunch

Seite 11

Escape 1800 Insert Installation and Operation Manual 19 4.3.3 Two Parallel Logs Place two spit logs in the firebox. Place a few sheets of twisted n

Seite 12

Escape 1800 Insert Installation and Operation Manual 2 THANK YOU FOR CHOOSING THIS DROLET WOOD INSERT As one of North America’s largest and m

Seite 13 - 3 Fuel

Escape 1800 Insert Installation and Operation Manual 20 IF YOU MUST OPEN THE DOOR WHILE THE FUEL IS FLAMING, OPEN THE AIR CONTROL FULLY

Seite 14

Escape 1800 Insert Installation and Operation Manual 21 4.4.4 Firing Each New Load Hot Place the new load of wood on and behind the charcoal, and n

Seite 15

Escape 1800 Insert Installation and Operation Manual 22 4.5 Fan Operation Allow the insert to reach operating temperature (approximately one hour),

Seite 16 - 3.3 Manufactured Logs

Escape 1800 Insert Installation and Operation Manual 23 4.5.1.4 Maximum Burn Cycle Times The burn cycle time is the period between loading

Seite 17 - 4 Operating Your Insert

Escape 1800 Insert Installation and Operation Manual 24 5 Maintaining Your Wood Heating System 5.1 Insert Maintenance Your new insert will give ma

Seite 18

Escape 1800 Insert Installation and Operation Manual 25 5.1.2 Door adjustment In order for your insert to burn at its best efficiency, the door mus

Seite 19 - 4.4 Maintaining Wood Fires

Escape 1800 Insert Installation and Operation Manual 26 5.1.3 Replacing the Door Gasket It is important to maintain the gasket in good condition. A

Seite 20

Escape 1800 Insert Installation and Operation Manual 27 gasket. Peel off more of the backing and rotate the glass and press the next section onto th

Seite 21

Escape 1800 Insert Installation and Operation Manual 28 5.2.2 How Often Should You Clean the Chimney? It is not possible to predict how much or how

Seite 22 - 4.5 Fan Operation

Escape 1800 Insert Installation and Operation Manual 29 PART B - INSTALLATION 6 Pre-Installation Masonry fireplace requirements The masonry firepl

Seite 23

Escape 1800 Insert Installation and Operation Manual 3 Table of content PART A - OPERATION AND MAINTENANCE ... 6 1 Safet

Seite 24 - 5.1 Insert Maintenance

Escape 1800 Insert Installation and Operation Manual 30 3. CHIMNEY CAPS: Mesh type chimney caps must have provision for regular cleaning, or the me

Seite 25

Escape 1800 Insert Installation and Operation Manual 31 7.2 Regulations Covering Insert Installation When installed and operated as described in

Seite 26

Escape 1800 Insert Installation and Operation Manual 32 8 Clearances to Combustible Material The clearances shown in this section have been

Seite 27

Escape 1800 Insert Installation and Operation Manual 33 8.3 Compliance of a Combustible Mantel Shelf To ensure compliance of an existing mantel she

Seite 28

Escape 1800 Insert Installation and Operation Manual 34 8.4 Positioning the Unit It is necessary to have a floor protection made of non-combustible

Seite 29 - PART B - INSTALLATION

Escape 1800 Insert Installation and Operation Manual 35 If the extension of the masonry hearth is raised at least 4" (102mm) from

Seite 30 - 7 Safety Information

Escape 1800 Insert Installation and Operation Manual 36 There are two ways to calculate the R factor of the floor protection. First, by adding the R

Seite 31

Escape 1800 Insert Installation and Operation Manual 37 Thermal Characteristics of Common Floor Protection Materials* MATERIAL CONDUCTIVITY (k) PER

Seite 32

Escape 1800 Insert Installation and Operation Manual 38 When installed as an extended insert, the front edge of the air jacket will be installed flu

Seite 33

Escape 1800 Insert Installation and Operation Manual 39 8.5 Minimum Masonry Opening, Clearances to Combustibles, and Floor Protector

Seite 34 - 8.4 Positioning the Unit

Escape 1800 Insert Installation and Operation Manual 4 4.5 Fan Operation ...

Seite 35

Escape 1800 Insert Installation and Operation Manual 40 CLEARANCES F 16" (406 mm) G 12" (305 mm) H 20" (508 mm) I 22" (559 mm)

Seite 36

Escape 1800 Insert Installation and Operation Manual 41 9 The Venting System 9.1 General The venting system, made up of the chimney and the liner

Seite 37

Escape 1800 Insert Installation and Operation Manual 42 9.3 Suitable Chimneys Your wood insert will provide optimum efficiency and performance when

Seite 38

Escape 1800 Insert Installation and Operation Manual 43 9.5 Chimney liner installation The preferred methods for installing the chimney liner are f

Seite 39 - Protector

Escape 1800 Insert Installation and Operation Manual 44 B) Your dealer may offer a liner fastening system (AC02006), sold separately. Follow the in

Seite 40

Escape 1800 Insert Installation and Operation Manual 45 9.6 Minimum Chimney Height The top of the chimney should be tall enough to be above t

Seite 41 - 9 The Venting System

Escape 1800 Insert Installation and Operation Manual 46 9.8 Supply of Combustion Air In Canada, wood inserts are not required to have a supply of c

Seite 42 - 9.4 Liner installation

Escape 1800 Insert Installation and Operation Manual 47 Appendix 1: Blower Installation First, attach the fan assembly to the insert by aligni

Seite 43

Escape 1800 Insert Installation and Operation Manual 48 The fan has a rheostat, see the illustration on the right to identify the differ

Seite 44

Escape 1800 Insert Installation and Operation Manual 49 Appendix 2: Installing the Optional Fresh Air Intake Kit (AC01298) Note: Only remo

Seite 45 - 9.6 Minimum Chimney

Escape 1800 Insert Installation and Operation Manual 5 9.7 The Relationship Between the Chimney and the House ...

Seite 46

Escape 1800 Insert Installation and Operation Manual 50 Then, install the fresh air kit adapter (B) using 4 screws (C). Secure the flexible pipe (E)

Seite 47

Escape 1800 Insert Installation and Operation Manual 51 Appendix 3: Optional Faceplate and Decorative Trims Installation Note: The illustrati

Seite 48

Escape 1800 Insert Installation and Operation Manual 52 Insert the superimposed brackets (F) and (G) with the screws (H) in the groove

Seite 49 - (AC01298)

Escape 1800 Insert Installation and Operation Manual 53 Then align the holes in the faceplate extension (M) with the holes in each faceplate side pa

Seite 50

Escape 1800 Insert Installation and Operation Manual 54

Seite 51 - Installation

Escape 1800 Insert Installation and Operation Manual 55 Appendix 4: Optional Top Surround and Shelf Heat Shield Installation (AC01317) When a heat

Seite 52

Escape 1800 Insert Installation and Operation Manual 56 Appendix 5: Installing the Optional Fire Screen (AC01315) Open the door. Hold the fire

Seite 53

Escape 1800 Insert Installation and Operation Manual 57 Appendix 6: Installation of Secondary Air Tubes and Baffle 1. Starting with the rear tub

Seite 54

Escape 1800 Insert Installation and Operation Manual 58 Note that secondary air tubes (A) can be replaced without removing the baffle board (B).

Seite 55 - Installation (AC01317)

Escape 1800 Insert Installation and Operation Manual 59 Appendix 7: Removal instructions For the purpose of inspecting the insert itself or the fir

Seite 56

Escape 1800 Insert Installation and Operation Manual 6 PART A - OPERATION AND MAINTENANCE Please see Part B for installation instructions. 1 Safety

Seite 57

Escape 1800 Insert Installation and Operation Manual 60 Appendix 8: Exploded Diagram and Parts List

Seite 58 - Model Type of tube

Escape 1800 Insert Installation and Operation Manual 61 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your

Seite 59

Escape 1800 Insert Installation and Operation Manual 62 # Item Description Qty 36 30206 ZINC WASHER ID=5/16" x OD=3/4" 1 37 PL65537

Seite 60

Escape 1800 Insert Installation and Operation Manual 63 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the origin

Seite 61

Escape 1800 Insert Installation and Operation Manual 7 • DO NOT BURN: o GARBAGE OF ANY KIND, o COAL OR CHARCOAL, o TREATED, PAINTED OR COATED WOO

Seite 62

Escape 1800 Insert Installation and Operation Manual 8 2 General Information 2.1 Escape 1800 Insert Specifications Fuel Type Cordwood Test Stan

Seite 63

Escape 1800 Insert Installation and Operation Manual 9

Kommentare zu diesen Handbüchern

Keine Kommentare