45221 OWNER`S MANUAL Escape 1400-I Insert US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT Verified and tested following
9 2.4 Installation Instructions 1. Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or u
10 2.5 Air control plate, faceplate and fan Assembly Instructions 1. Place the faceplate panels with the finished side down on a flat, soft, non-a
11 2.6 Installation of the adapter for fresh air kit In order to avoid some combustion problems, it is highly recommended to install an adapter for f
12 Section 3.0 Operation 3.1 Safety Information 1. This insert is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or modifying t
13 air leakage into the unit, such as through deteriorated gaskets or cracked or broken glass. Do not operate the insert without a door gasket. Leak
14 An example of the energy values of some common wood fuels is given in Table 3.1 For recommended wood sizes, refer to the specifications. Common H
15 6. Ideally the large kindling should be burned until a thick bed of red embers is obtained. At that point, add cordwood fuel and continue to oper
16 3.5 Maintaining The Fire Your Drolet insert will work best if a thick bed of hot embers is maintained in the bottom of the firebox, and a minimum
17 Section 4.0 Maintenance 4.1 Care And Cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to cl
18 4.2 Ash Removal CAUTION: Ashes can start fires, even after several days of inactivity. Never dispose of ashes in a combustible container. Remov
1 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase
19 4.4 Baffle Installation for Escape 1400-I Figure 4.1 – Baffle installation & removal for Escape 1400-I The baffle assembly must
20 4.5 Secondary Air Tube Replacement (see Figure 4.3) 1. Remove cotter pin at RH end of tube. 2. Slide tube to left and lower tube end below RH p
21 4.6 Fan Maintenance & Care Clean the fan air inlet louvres and squirrel cage impeller regularly. The fan should be kept clean and dust free.
22 Section 5.0 Specifications 5.1 Escape 1400-I Insert Model Fuel Type Cordwood Test Standards ULC S628 (CSA B366.2) & UL 1482 residen
23 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This w
2 TABLE OF CONTENTS INTRODUCTION ...
3 Escape 1400-I Dimensions 13 29/64"28 25/64"26 29/32"6.000"O 9 61/64"20 31/32"13 3/8"6 31/64"8 9/32"
4 Section 1.0 Pre-Installation Requirements 1.1 Masonry & Zero Clearance Requirements The masonry fireplace must meet the minimum code requiremen
5 1.2 Venting Requirements The flue is a critical component to a satisfactory installation. Your insert will attain its best performance if installe
6 Section 2.0 Installation 2.1 Clearances To Combustibles (Measured From Insert Body) Escape 1400-I Sidewall (A) 13” (330 mm) 14” (356mm) Top ma
7 2.1.1 Hearth Requirements If the non-combustible hearth is flush with the floor, then the hearth must be 16”/406mm (18”/450mm in Canada) in fro
8 2.3 Safety Information NOTE: This appliance is not recommended for use in a home if an occupant has any respiratory or any other related problems.